Hello Ram,
thanks. Some suggestions on the parameters:
For the parameter T100_MESS you should use a message ID which is defined in the transaction SE91.
For the parameter WHERECLAUSE2 could you please remove "space", it should look like ARFCSTATE='SYSFAIL'.
For the parameter RESCANFROMBEGIN please check the note:
1677348 - Table monitoring terminates when started
In this parameter a name of the column in the table should be defined. Does such column (ende) exist in the table, which you need to monitor?
After you have make changes to the parameters and stored the method definition please reset the monitoring segment in 'WARMUP' status and check again the selfmonitoring structure in RZ20 if the method still terminates. You can reset the segment in "RZ21 --> Topology --> Segment Overview --> Display Overview", then "change mode", then select the segment of the instance, where table monitoring MTEs are located, and press the button "Reset Segment in "WARMUP" Status".
Regards,
Alwina