Hi
For every event linkage in SWE2, set the flag "Behaviour on Error Feedback" to "0 - System Defaults" or "3 - Do not Change Linkage"
If you set it to "0 - System Defaults", then make sure you go to SWEQADM -> Tab Basic Data-> Set Reciever error feedback to "3 - Do not Change Linkage".
SWE2 settings override SWEQADM Settings in this case.
Regards,
Modak